evikon

EVIKON We are authorized distributor for M/s Evikon MCI OU

  • Oxygen transmitter
  • Combustible gases transmitter
  • Hydrogen Sensor/transmitter

Oxygen sensor

fire-alarm-system gas-suppression

E2618-O2

Features
  • Electrochemical sensor
  • Range 0...25 %vol O2
  • Resolution 0,01 %vol O2
  • 2 × 4-20 mA or 0-10 V, RS485

Description

Oxygen transmitter E2618-O2 is a member of new PluraSens® family of multifunctional measurement instruments. The instrument may be used to prevent critical decrease of O2 concentration as well as to control the absence of the oxygen in gas mixtures. The instrument utilises a fully calibrated and temperature compensated gas sensor with excellent repeatability, stability and long lifetime. Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the transmitter to safety or building automation systems.

Technical Data

Calibration oxygen O2
Sensor type electrochemical
Sampling method diffusion
Detection range 0...25 %vol O2
Resolution 0,01 %vol O2
Sensor lifetime > 2 years
Power supply 12...36 VDC (default)
24 VAC as option
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H82 × W80 × D55 mm
Operating conditions -30...+50 °C, 15...90 %RH

Hydrogen detector

fire-alarm-system
Features
  • Stable long-life metal-oxide / pellistor sensor
  • Range 0...100% LEL
  • Resolution 0,1 / 1 % LEL
  • Two SPST relays
  • 2 × 4-20 mA or 0-10 V, RS485

Description

Combustible gas detector-transmitter E2608-LEL is a member of new PluraSens® family of multifunctional measurement instruments. The device exhibits sensitivity to hydrogen, methane, acetylene, propane and butane. Applications include underground parkings, boiler houses, battery charging rooms, kitchens, and other confined spaces, where potentially explosive concentration of combustible gases can accumulate. The instrument utilises fully calibrated metal-oxide semiconductor or pellistor gas sensors with excellent repeatability, stability and long lifetime. Two relays with closing contact may be used for remote signalling or ventilation control. Two alarm set-points are user settable. Two analog outputs and RS485 digital interface with industry standard Modbus RTU protocol can be used to connect the detector to safety or building automation systems.

Technical Data

Detected gases hydrogen, methane, acetylene, propane, butane
Default calibration methane CH4
Sensor type metal-oxide semiconductor (MOS)
pellistor (catalytic bead) on demand
Sampling method diffusion
Detection range 0...100% LEL
Resolution 0,1 / 1 % LEL
Accuracy ± 2% LEL
Sensor lifetime > 5 years (MOS)
> 3 years (pellistor)
Power supply 12...36 VDC (default),
24 VAC or 230 VAC as options
Digital interface RS485, Modbus RTU protocol
Analog outputs 2 × 4-20 mA / 0-10 V, user settable
Output relays 2 × SPST relays (closing contact),
250 VAC / 30 VDC, 5 A max
Default alarm set-points 20% LEL / 50% LEL CH4
Enclosure grey ABS plastic, wall mount, IP65
Dimensions H85 × W82 × D55 mm
Operating conditions 0...95 %RH
-40...+70 °C (MOS)
-10...+50 °C (pellistor)